Mission-Critical Infrastructure

Zero-Potable Cooling Water for AI & Hyperscale Data Centres

Solve the AI thermal bottleneck without exhausting municipal water tables. Tigreen's patented Radical Bubble Purification (RBP) reclaims up to 90% of wastewater, slashes cooling tower chemical additives by 60%+, and delivers strict ASHRAE WUE (< 1.3 m³/MWh) compliance in a compact, containerized footprint.

Zero Municipal Water RequiredNo Blowers or Compressors (< 60 dBA)Zero-CapEx WaaS Utility Model20ft & 40ft ISO Container Ready
The Mission-Critical Bottleneck

The Global AI Heat vs. Water Paradox

High-density GPUs (H100/B200 clusters) require millions of litres of daily heat rejection. As municipal utilities impose severe moratoria, data centres face an existential water crisis.

Municipal Water Bans & Penalties

From Northern Virginia and Phoenix to Frankfurt and Bengaluru, cities are rejecting data centre permits or levying punitive utility surcharges on drinking water consumed by evaporative cooling towers.

Cooling Tower Scaling & Chemical Costs

Raw municipal or tanker water contains high dissolved solids and biological load, leading to rapid scaling, condenser tube fouling, and massive chemical expenditure to prevent corrosion and Legionella outbreaks.

2030 "Water Positive" Mandates

Hyperscale operators (Microsoft, Google, AWS, Meta) have legally binding commitments to replenish 100%+ of their water consumption by 2030. Unaudited groundwater pumping puts colocation leases at risk.

Proprietary RBP Chemistry

How Tigreen Transforms Cooling Tower Operations

Our patented Radical Bubble Purification (RBP) nozzle eliminates biological growth and micro-contaminants at the molecular level, delivering superior process water for HVAC loops.

60%+ Reduction in Cooling Water Chemical Additives

By removing organic precursors, TSS, and heavy metallic ions, Tigreen process water drastically reduces the need for expensive anti-scalants, biocides, and corrosion inhibitors in the primary condenser loop.

Higher Cycles of Concentration (CoC: 8x–10x)

Standard water limits cooling towers to 3x–4x cycles before blowdown must be dumped to prevent fouling. Tigreen water allows 8x to 10x cycles, cutting tower blowdown discharge volumes by up to 80%.

Zero Blowers: Whisper-Quiet < 60 dBA Operation

Unlike conventional aeration tanks that produce severe low-frequency hums and vibration, our hydraulic radical nozzles eliminate mechanical blowers, operating silently beside critical server rooms and generator bays.

Automated Modbus IoT & WUE Audit Telemetry

Integrated edge client with local SQLite store-and-forward buffering. Continuous telemetry tracks flow rates, conductivity, pH, and avoided municipal extraction, generating certified VWBA replenishment audit logs.

Closed-Loop Water Architecture

Data Centre Cooling Loop Integration

STEP 1: Wastewater Inflow (Greywater / STP / Blowdown)

Interception of secondary facility effluent, greywater from campus, and cooling tower blowdown.

STEP 2: Tigreen RBP Hydraulic Microbubble Stage

Microbubbles (<10 µm) generate •OH hydroxyl radicals, oxidising organic contaminants, oils, and surfactant complexes with zero blower energy.

STEP 3: Micro-Sludge Flotation & Surface Skimming

Concentrated solids and surfactants float to the surface for automatic skimming. Less than 10% the sludge volume of conventional plants.

STEP 4: Polished Makeup Water to Cooling Towers

Ultra-pure, low-TDS water fed directly to HVAC chillers and cooling towers, delivering WUE < 1.3 m³/MWh.

Standard Models & Custom Engineering

Standard Skids & Custom-Built Plants

Choose from 4 pre-engineered packaged units (20 to 500 KLD) or request a custom-fabricated system up to 1,000+ KLD built to fit your site dimensions and effluent chemistry.

TG-6020ft Skid / Basement Modular FrameZero Civil Work Required

Handles 60,000 litres daily inside 18 m², saving up to ₹25 Lakhs annually in water tanker bills.

Daily Capacity
60 KLD
15,850 GPD / day
Flow Rate
3,000 LPH
Continuous Hydraulic Inflow
Connected Power
4.5 kW
40–50% less power (No Blowers)
Physical Footprint
190 sq ft
18 m² (85-90% space saved)
Real Estate Footprint Comparison

Tigreen TG-60 vs. Conventional ETP/STP

Saves up to 90% valuable industrial land
Tigreen TG-60 Footprint190 sq ft (18 m²)
Conventional Biological ETP / STP Plant2,500+ sq ft (Civil tanks & clarifiers)
BOD / COD RemovalUp to 96% (Outlet < 5 mg/L) BOD | 75–85% (Outlet < 20 mg/L) COD
Acoustic Noise Rating< 58 dBA (No air blowers)
Delivery & Commissioning35–45 days (Target ROI: 18–20 months)
Ideal Industrial Typology100-Flat Apartments, 150-Bed Hospitals, Food Processing, Commercial Malls
Commercial OptionsDirect Equipment Sale or Zero-CapEx WaaS
IoT & Telemetry ReadinessModbus TCP + Store-and-Forward Telemetry

Tigreen Standardized SKUs — Engineering Quick Reference

All models are skid-mounted, pre-wired, pre-plumbed, and zero-civil ready.

ISO Container Compatible
ModelDaily VolumeFlow RateFootprintConnected PowerLead TimeTarget Applications
TG-2020 KLD5,280 GPD1,000 LPH130 sq ft(12 m²)2 kW30–45 daysBoutique Apartments (15–40 Flats), Clinics, Hotels, Small Laundries
TG-6060 KLD15,850 GPD3,000 LPH190 sq ft(18 m²)4.5 kW35–45 days100-Flat Apartments, 150-Bed Hospitals, Food Processing, Commercial Malls
TG-120120 KLD31,700 GPD6,000 LPH235 sq ft(22 m²)6.5 kW45–60 daysTier-2/3 Data Centres, Textile & Dyeing Units, IT Tech Parks, Industrial Campuses
TG-500 / Custom500 KLD132,000 GPD25,000 LPH540 sq ft(50 m²)18 kW60–90 daysHyperscale AI Data Centres, Industrial Parks, Mega Townships & Custom Retrofits
Custom Built10 – 1,000+ KLDAny flow rate500 – 50,000+ LPHBuilt to basement / yard spaceSized to loadCustom quoteExisting MBBR tank retrofits, odd-shaped basements, high-COD chemical & pharma streams
Empirical Performance

Cooling Water Source Comparison Matrix

How Tigreen containerized process water compares against traditional water supply methods for data centres and high-density industrial facilities.

Operational CriteriaMunicipal Potable MainsPrivate Tankers / Deep WellsConventional Biological STPTigreen RBP Process Water
Supply Reliability & UptimeUnreliable (Subject to drought cuts)Highly Volatile (Traffic & cartel risks)Fluctuating (Frequent biological shock)99.9% Reliable (Continuous on-site loop)
Cooling Tower Chemical AdditivesBaseline HighExtremely High (Hardness scaling)High (Bio-fouling & odor risk)60%+ Reduction (Low TDS & zero bio-load)
Physical Footprint (500 KLD)N/A (External piping)Tanker unloading yards needed2,500 – 3,500 sq ft (Concrete tanks)300 sq ft (Single 40ft ISO Container)
Civil Construction Time3–6 months for utility linesNone6–12 months heavy civil worksZero Civil Work (Delivered in 45–90 days)
Energy ConsumptionPumping onlyFuel intensive (Fleet transit)High (Continuous 24/7 blowers)40–50% Lower (Hydraulic microbubbles)
Acoustic Noise / VibrationLowTruck noiseHigh (Heavy compressor drone)< 60 dBA (Whisper Quiet, No Blowers)
Corporate ESG & 2030 Water PositiveNegative (Depletes municipal reserves)Severely Negative (Groundwater depletion)Neutral (Often not certified for cooling)100% Water Positive (Audited VWBA Credits)
Commercial ModelVariable tariffs + peak surchargesFluctuating spot pricesHeavy upfront CapEx + costly O&MZero-CapEx WaaS (Pay per m³ / kL produced)
Commercial Delivery Model

Zero-CapEx Water as a Service (WaaS)

Data centre operators shouldn't have to become wastewater treatment specialists. Under our BOOT (Build-Own-Operate-Transfer) model, Tigreen funds, installs, and runs the entire recycling infrastructure.

01

Zero Capital Expenditure

Tigreen manufactures and installs the containerized RBP unit at your facility with zero upfront capital outlay. All engineering, piping integration, and commissioning costs are absorbed by us.

02

Guaranteed Water Quality SLA

You pay a predictable, metered tariff strictly for the cubic meters of cooling-grade water delivered. Continuous IoT telemetry provides real-time verification of TDS, pH, and flow rate compliance.

03

100% Tigreen Managed O&M

Our certified field engineers handle all periodic maintenance, sensor calibration, and consumable upkeep. 24/7 remote cloud monitoring ensures zero unplanned chiller downtime.

Ready to eliminate potable water from your cooling infrastructure?

Our engineering team will conduct a comprehensive water audit of your facility and provide a tailored WaaS proposal within 5 business days.

Support & Info

Data Centres & Mission-Critical Cooling — FAQs

Data centre evaporative cooling systems require substantial volumes of makeup water. Tigreen's RBP technology reclaims on-site greywater and utility blowdown, converting it into ultra-pure, low-TDS cooling water. By bypassing municipal drinking water mains and preventing tower blowdown losses, facilities achieve strict ASHRAE WUE (< 1.3 m³/MWh) compliance without sacrificing thermal headroom.

Conventional makeup water contains high dissolved solids, silica, and bio-organic loads that cause scaling and Legionella risks in cooling loops, requiring heavy doses of anti-scalants, corrosion inhibitors, and biocides. Tigreen's radical microbubble oxidation strips organics, suspended solids, and heavy mineral complexes at the source, allowing cooling towers to run at 8x to 10x cycles of concentration (CoC) with minimal chemical conditioning.

Yes. A 120 KLD unit (TG206) occupies only 60 sq ft, while our 500 KLD unit (TG225) fits within a standard 40ft ISO container (300 sq ft). Unlike biological plants, Tigreen requires zero civil concrete basins, generates zero odor, and operates without air blowers/compressors, maintaining noise levels below 60 dBA adjacent to mission-critical infrastructure.

Under our Zero-CapEx WaaS model, Tigreen finances, manufactures, installs, and operates the containerized reclamation plant. The data centre pays a predictable, metered tariff per cubic meter ($/m³ or ₹/kL) of verified cooling-grade water produced. This completely removes capital expenditure hurdles and guarantees operational water uptime.

Every Tigreen containerized unit integrates with our industrial IoT edge gateway (Modbus TCP PLC poller). Real-time telemetry continuously logs flow rate, pH, conductivity, and dissolved solids with offline buffering. Data centres receive automated, audit-ready compliance certificates satisfying corporate 2030 Water-Positive pledges and ISO 14001 standards.